Pure Sine Wave Inverter 350W/500W/800W/1000W
Energy storage product for B2B applications
View Details →
Advanced energy storage product engineered for reliable power applications, scalable supply, and global B2B project requirements.
Provides stable pure sine wave output with automatic self-diagnostics, generator start control, AVR voltage regulation, and auto-restart functionality. Adjustable charging current and compatibility with both lead-acid and lithium batteries ensure efficient, flexible, and reliable power performance for a wide range of backup power applications.

| MODEL | HB0512 | HB0812 | HB1012 | HB1512 | HB1524 |
|---|---|---|---|---|---|
| BASIC PARAMETERS | |||||
| System Capacity | 500VA | 800VA | 1000VA | 1500VA | 1500VA |
| Rated Output Power | 400W | 640W | 800W | 1200W | 1200W |
| AC INPUT | |||||
| AC Input Voltage | 220VAC / 110VAC | ||||
| Input Voltage Range | 220V: 145–275VAC ±3V 110V: 73–137VAC ±3V |
||||
| Input Frequency | 50 / 60Hz ±5% | ||||
| AC MODE OUTPUT | |||||
| AC Mode Output Voltage | Same as Input Voltage | ||||
| AC Mode Output Frequency | Same as Input Frequency | ||||
| BATTERY MODE OUTPUT | |||||
| Battery Mode Output Voltage | 220VAC ±10% / 110VAC ±10% | ||||
| Battery Mode Output Frequency | 50Hz or 60Hz ±1% | ||||
| Output Waveform | Pure Sine Wave | ||||
| BATTERY & CHARGING | |||||
| Battery Type | Lead-acid Battery / Water Battery / Lithium Battery | ||||
| Battery Voltage | 12VDC | 12VDC | 12VDC | 12VDC | 24VDC |
| Battery Charging Voltage | 13.75VDC | 13.75VDC | 13.75VDC | 13.75VDC | 27VDC |
| Max AC Charging Current | 8A | 13A | 18A | 30A | 15A |
| AC Charging Input Voltage Range | 150–280VAC | ||||
| SYSTEM OPERATION | |||||
| Transfer Time | ≤10ms | ||||
| Load Peak Ratio | Max. 3:1 | ||||
| ECO Mode Power | 6W | 8W | 9W | 11W | 12W |
| PROTECTION | |||||
| Protection Functions | Overload Protection / Short-circuit Protection / Low-voltage Protection / Battery Reverse-connection Protection | ||||
| DISPLAY & ALARM | |||||
| Status Display | AC Voltage / AC Frequency / Output Frequency / Battery Voltage / Load Current | ||||
| Low Battery Alarm | Low-battery protection: long buzzer alarm. Low battery: buzzer sounds every second. |
||||
| Overload Alarm | Overload below 130%: buzzer sounds every second. Overload above 150%: output shuts down after approximately 300ms. |
||||
| Fault Alarm | Machine Fault – Long Buzzer Alarm | ||||
| ENVIRONMENTAL CONDITIONS | |||||
| Operating Temperature | 0°C to 40°C | ||||
| Storage Temperature | -15°C to 45°C | ||||
| Relative Humidity | 10%–90% RH, Non-condensing | ||||
| Noise | <45dB | ||||
| MECHANICAL | |||||
| Dimensions | 300 × 144 × 213mm | ||||
| Net Weight | 6.5kg | 6.9kg | 7.8kg | 8.59kg | 9.5kg |
Energy storage product for B2B applications
View Details →
Energy storage product for B2B applications
View Details →
Read the latest updates on battery cells, portable power stations, solar energy systems, residential storage, commercial ESS, manufacturing capability, and global energy storage applications.
Loading latest articles...